Skip to content

TMS (Transcranial Magnetic Stimulation)

TMS (Barker 1985) uses fast-changing magnetic fields to induce electrical current in the brain, non-invasively activating / inhibiting cortex regions. Important clinical + research tool today: depression treatment, causal brain mapping, cognitive enhancement.

Difficulty: Intermediate Prerequisites: Cortex, electromagnetism basics


1. Principle

Faraday electromagnetic induction: changing magnetic field → induces electric field.

Capacitor discharge → coil → strong short magnetic pulse (~1 T, 100 μs)
                    ↓
              Induces E-field in brain tissue
                    ↓
              Neurons depolarize → spike

→ No skull / scalp incision needed.


2. Types

  • Single-pulse TMS: single pulse, causal probing
  • Paired-pulse TMS: tests cortical inhibition
  • Repetitive TMS (rTMS): pulse sequences
  • High-frequency (5-20 Hz): excites cortex
  • Low-frequency (1 Hz): inhibits cortex
  • Theta-burst (TBS): short 50Hz bursts at 5Hz → strong + brief

3. Coil Shapes

  • Circular coil: shallow + diffuse
  • Figure-8 coil: focal + precise (~1 cm² target)
  • H-coil: deeper (5 cm vs 2 cm)

4. Clinical Applications

4.1 Depression (FDA-approved 2008)

  • High-frequency rTMS on left dlPFC
  • 5 days/week × 4-6 weeks
  • 30-40% response rate (vs drug + therapy resistance)

4.2 OCD (FDA 2018)

  • Deep TMS on mPFC/ACC

4.3 Migraine (FDA 2014)

  • Single-pulse TMS at-home device

4.4 Stroke Rehabilitation

  • Stimulate injured side → enhance motor recovery

4.5 Experimental

  • Schizophrenia, PTSD, addiction (research stage)

5. Research (Causal Mapping)

TMS is a causal tool, not correlation:

TMS on Broca → briefly disrupts speech → causal
fMRI Broca active in speech → only correlation
  • TMS on V1 → blindness for ms
  • TMS on M1 hand area → involuntary finger twitch (MEP)
  • TMS on dlPFC → working memory disruption

6. Safety

  • Main risk: seizure (rare, < 1/1000 in healthy)
  • Exclusions: epilepsy history, metal implants, pregnancy
  • Standard protocols are safe

7. vs tDCS / DBS

Aspect TMS tDCS DBS
Invasive No No Surgery needed
Precision High (cm) Low Very high (mm)
Duration Minutes Short Continuous
Intensity High Very low Strong
Clinical Depression+ Experimental Parkinson, OCD

8. Mechanism — Incomplete

  • Direct spike (in M1) → MEP
  • LTP-like changes (rTMS cumulative effects)
  • Network modulation
  • Neurochemistry (DA, GABA)

9. PyTorch / Python — TMS Pulse Simulation

import numpy as np
import matplotlib.pyplot as plt

def tms_pulse(t, peak_T=1.0, decay_us=100):
    t_us = t * 1e6
    return peak_T * np.sin(2 * np.pi * t / (decay_us * 1e-6)) * np.exp(-t_us / decay_us)

t = np.linspace(-50e-6, 200e-6, 1000)
B = tms_pulse(t)
plt.plot(t * 1e6, B)
plt.xlabel('Time (μs)')
plt.ylabel('Magnetic Field (T)')

10. Common Pitfalls

10.1 Target Uncertainty

Coil localization ± 5 mm — can't guarantee hitting specific cortical region.

10.2 Coil Heating

Long protocols → coil overheating.

10.3 Subject Variability

Need individualized intensity (MEP threshold).

10.4 Acoustic Effect

TMS click → 50 dB auditory stimulation, confound must be controlled.

10.5 Placebo

Sham TMS has similar effects — double-blind essential.



References

  1. Barker, A. T. et al. "Non-invasive magnetic stimulation of human motor cortex." Lancet, 1985.
  2. Pascual-Leone, A. et al. "Transcranial magnetic stimulation in cognitive neuroscience." Annu Rev Neurosci, 2000.
  3. Rossi, S. et al. "Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research." Clin Neurophysiol, 2009.
  4. George, M. S. et al. "Daily left prefrontal transcranial magnetic stimulation therapy for major depressive disorder." Arch Gen Psychiatry, 2010.